This error can have many different origins and does not necessarily mean
something is broken. When a hardware stow is issued for instance, the drive
error triggers as well, because the ACC is no longer in control of the drives. The
hardware stow can be issued manually by setting the stow switch on the PMON
rack in Narrabri, or when the anemometers on the dish register winds in excess
of 45km/h, or when the Mopra protect script detects lightning and/or wind above
threshold values, a hardware storm stow is also triggered.
9.3.10. MOPS B5 module error
Message ID: 23
Triggers when: the B5 module indicates an error
The message provides detailed recovery information on how to reactivate the B5
9.3.11. MOPS B6 module error
Message ID: 24
Triggers when: B6 Pol A or B sampler levels are dropping below 0.1V
This message indicates no signal is being fed down the conversion chain.
9.3.12. Turret rotation control is not in remote
Message ID: 25
Triggers when: The turret is in local mode and cannot be rotated.
You will not be able to change receivers. Apart from that, your observations will
not be affected.
9.3.13. Focus control is not in remote
Message ID: 26
Triggers when: The focus control is in local mode.
You will not be able to change the focus.
9.3.14. MOPRA PROTECT Hardware Stow
Message ID: 30
Triggers when: Mopra protect has issued a hardware stow.
This stow cannot be overridden, you have to wait for it to be released.